Chemical Storage Buildings

Chemical Storage Lockers & Buildings

Securall offers a complete line of safety storage buildings specifically designed for storing agri-chemicals and equipment safely. All buildings are designed to help you comply with safety rules when mixing and handling pesticides. These specially designed buildings are perfect for Golf Courses, Farms, Nurseries, Greenhouses and Landscape Contractors. Securall buildings help reduce the risk of poisoning and injuries among pesticide handlers and agricultural employees and will also help you protect against chemical spills, children and animal poisonings, theft, fire and unauthorized personnel.

Shelving & Lighting - Chemical Storage lockers/buildings comes with 3 tiers of shelving. Interior & Exterior lighting, a receptacle and load center.

Easy To Ship Securall's Chemical Storage Buildings (AG1200 and Below) are designed to fit in a standard high cube shipping container reducing shipping costs and labor time.

Buy Securall Cabinets at GSA Advantage

Hazardous Chemical Storage Reporting Requirements - Hazardous chemicals are any substances for which a facility must maintain a Material Safety Data Sheet (MSDS) under the OSHA Hazard Communication Standard, which lists the criteria used to identify a hazardous chemical. MSDSs are detailed information sheets that provide data on health hazards and physical hazards of chemicals along with associated protective measures. Hazardous chemical used or stored in the workplace, facilities must maintain a material safety data sheet (MSDS), and submit the MSDSs (or a list of the chemicals) to their State Emergency Response Commission (SERC), Local Emergency Planning Committee (LEPC) and local fire department. Any facility required under Occuptational Safety and Health Administration (OSHA) regulations to maintain material safety data sheets (MSDSs) for hazardous chemicals stored or used in the work place.
Biohazardous Waste Storage Buildings

Biohazard waste is short for biohazardous waste and is also known as biomedical waste. Biohazard waste is any biological waste that is potentially infectious. Biohazardous waste is any waste saturated with liquid or semi-liquid blood or other potentially infectious materials (OPIM). Often, biohazardous waste is used interchangeably with such terms as regulated medical waste, biomedical waste, clinical waste, infectious waste and may vary in local or state regulations. We offer modular, prefabricated hazardous material storage buildings and design/build solutions to help you achieve compliance with complex safety and environmental regulations for biomedical waste storage. Biomedical waste shall be segregated from other wastes.
Biomedical waste shall be stored in a manner that preserves the integrity of the container and is not conducive to rapid microbial growth and/or putrefaction. Pathological waste, cultures, and discarded animal carcasses and body parts stored for more than 24 hours after packaging shall be refrigerated at a temperature of 45° F or below in a refrigerator or refrigerated space used only for biomedical waste.

EPA Dos and Don'ts - Water Treatment Chemicals Storage
Do not store liquid chemicals and dry chemicals together regardless of which compatibility group they fall into.
Do not store chemicals from different compatibility groups together. Water treatment chemicals are divided into six incompatible groups: Acids, Bases, Salts & Polymers, Adsorption Powders, Oxidizing Powders, and Compressed Gasses. To ensure the safety of system personnel and the system itself, store each of these groups of incompatible chemicals separately.
Warning - Do not store products such as paint, antifreeze, detergent, oil, grease, fuel, solvent, and beverages in the same area as water treatment chemicals.
Calcium Hypochlorite, a combination base/oxidizer should not be exposed to moisture or mixed with viscous fluid such as oil - Excessive heat, fire or explosion possible. Can provide an ignition source for combustible materials.
Warning - Concentrated Sulfuric Acid, a strong acid, should not be mixed with Concentrated Sodium Hydroxide, a strong base - Excessive heat and liquid explosion. Note: Highly concentrated acids and bases when mixed together will have a much more hazardous reaction than weak acids and bases.
Common Water Treatment Chemicals - Sodium Hypochlorite, Calcium Hypochlorite, Calcium Hydroxide, Calcium Oxide, Sodium Bicarbonate, Sodium Carbonate, Chlorine, Sulfur Dioxide, Potassium Permanganate.
  • 68.4 Cubic Feet CHEMICAL STORAGE LOCKER

    AG200 - 68.4 Cubic Feet Chemical Storage Locker; Sump Capacity 55 Gal.; Exterior Dimension 7'H x 5'W x 3'6"D; Approx. Ship. Wt. 1,431 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                             

    OPFR2-200 - 2 Hour Fire Rating Upgrade ; Approx. Ship. Wt. 1,298 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-200 - 4 Hour Fire Rating Upgrade ; Approx. Ship. Wt. 1,722 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           


  • 145.1 Cubic Feet CHEMICAL STORAGE LOCKER

    AG400 - 145.1 Cubic Feet Chemical Storage; Sump Capacity 68 Gal.; Exterior Dimension 7'H x 5'W x 5'D; Approx. Ship. Wt. 1,898 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                              

    OPFR2-400 - 2 Hour Fire Rating Upgrade; Approx. Ship. Wt. 1,363 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-400 - 4 Hour Fire Rating Upgrade ; Approx. Ship. Wt. 1,878 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design          


  • 211.4 Cubic Feet CHEMICAL STORAGE LOCKER

    AG600 - 211.4 Cubic Feet Chemical Storage; Sump Capacity 102 Gal.; Exterior Dimension 8'4"H x 7'W x 5'D; Approx. Ship. Wt. 2,236 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                              

    OPFR2-600 - 2 Hour Fire Rating Upgrade ; Approx. Ship. Wt. 2,239 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-600 - 4 Hour Fire Rating Upgrade ; Approx. Ship. Wt. 2,973 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           


  • 308.1 Cubic Feet CHEMICAL STORAGE LOCKER

    AG900 - 308.1 Cubic Feet Chemical Storage; Sump Capacity 154 Gal.; Exterior Dimension 8'4"H x 7'W x 7'D; Approx. Ship. Wt. 2,742 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                              

    OPFR2-900 - 2 Hour Fire Rating Upgrade ; Approx. Ship. Wt. 2,712 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-900 - 4 Hour Fire Rating Upgrade ; Approx. Ship. Wt. 3,604 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           


  • 404.7 Cubic Feet CHEMICAL STORAGE LOCKER

    AG1200 - 404.7 Cubic Feet Chemical Storage; Sump Capacity 206 Gal.; Exterior Dimension 8'4"H x 7'W x 9'D; Approx. Ship. Wt. 3,375 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                               

    OPFR2-1200 - 2 Hour Fire Rating Upgrade ; Approx. Ship. Wt. 3,059 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-1200 - 4 Hour Fire Rating Upgrade ; Approx. Ship. Wt. 4,108 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

  • 524.1 Cubic Feet CHEMICAL STORAGE BUILDING

    AG1600 - 524.1 Cubic Feet Chemical Storage; Sump Capacity 272 Gal.; Exterior Dimension 8'4" H x 10' W x 8' D; Approx. Ship. Wt. 5,226 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                               

    OPFR2-1600 - 2 Hour Fire Rating Upgrade; Approx. Ship. Wt. 3,253 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-1600 - 4 Hour Fire Rating Upgrade; Approx. Ship. Wt. 3,8698 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           


  • 747.7 Cubic Feet CHEMICAL STORAGE BUILDING

    AG2400 - 747.7 Cubic Feet Chemical Storage; Sump Capacity 393 Gal.; Exterior Dimension 8'4"H x 14'W x 8'D; Approx. Ship. Wt. 6,443 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                             

    OPFR2-2400 - 2 Hour Fire Rating Upgrade; Approx. Ship. Wt. 3,600 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-2400 - 4 Hour Fire Rating Upgrade; Approx. Ship. Wt. 5,107 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           


  • 971.3 Cubic Feet CHEMICAL STORAGE BUILDING

    AG3200 - 971.3 Cubic Feet Chemcial Storage; Sump Capacity 514 Gal.; Exterior Dimension 8'4"H x 18'W x 8'D; Approx. Ship. Wt. 8,030 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                               

    OPFR2-3200 - 2 Hour Fire Rating Upgrade; Approx. Ship. Wt. 4,356 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-3200 - 4 Hour Fire Rating Upgrade; Approx. Ship. Wt. 6,194 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design          


  • 1,277.3 Cubic Feet CHEMICAL STORAGE BUILDING

    AG3800 - 1,277.3 Cubic Feet Chemical Storage; Sump Capacity 636 Gal.; Exterior Dimension 8'4"H x 22'W x 8'D; Approx. Ship. Wt. 9,520 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                               

    OPFR2-3800 - 2 Hour Fire Rating Upgrade; Approx. Ship. Wt. 6,090 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-3800 - 4 Hour Fire Rating Upgrade; Approx. Ship. Wt. 8,258 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           


  • 1,418.5 Cubic Feet CHEMICAL STORAGE BUILDING

    AG4800 - 1,418.5 Cubic Feet Chemical Storage; Sump Capacity 757 Gal.; Exterior Dimension 8'4"H x 26'W x 8'D; Approx. Ship. Wt. 10,566 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                               

    OPFR2-4800 - 2 Hour Fire Rating Upgrade; Approx. Ship. Wt. 7,823 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-4800 - 4 Hour Fire Rating Upgrade; Approx. Ship. Wt. 10,322 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           


  • 1,865.7 Cubic Feet CHEMICAL STORAGE BUILDING

    AG6400 - 1,865.7 Cubic Feet Chemical Storage; Sump Capacity 1,000 Gal.; Exterior Dimension 8'4"H x 34'W x 8'D; Approx. Ship. Wt. 13,584 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                               

    OPFR2-6400 - 2 Hour Fire Rating Upgrade; Approx. Ship. Wt. 9,616 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-6400 - 4 Hour Fire Rating Upgrade; Approx. Ship. Wt. 12,777 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           


  • 2,313 Cubic Feet CHEMICAL STORAGE BUILDING

    AG8000 - 2,313 Cubic Feet Chemical Storage; Sump Capacity 1,234 Gal.; Exterior Dimension 8'4"H x 42'W x 8'D ; Approx. Ship. Wt. 15,301 Lbs.
    Approval - OSHA, FM, NFPA    |   View Details                               

    OPFR2-8000 - 2 Hour Fire Rating Upgrade; Approx. Ship. Wt. 11,737 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

    OPFR4-8000 - 4 Hour Fire Rating Upgrade; Approx. Ship. Wt. 15,537 Lbs.
    Approval - Intertek Tested and FM Approved Wall & Roof Design           

** Images may be shown with optional accessories **