Fire Rating & Explosion Relief Panel
OPFR2-200 2 Hour Fire Rating Upgrade; Approx. Ship. Wt. 1,298 Lbs.
Industry's 1st & Only Intertek Tested and FM Approved 2 hrs fire rated wall construction built with 1.5 hour fire rated roof construction, 1.5 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.
OPFR4-200 4 Hour Fire Rating Upgrade; Approx. Ship. Wt. 1,722 Lbs.
Industry's 1st & Only Intertek Tested and FM Approved 4 hrs fire rated wall construction built with 3 hour fire rated roof construction, 3 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.
OPXRP-200 Explosion Relief Panel; 1-48" X 60"
Used in the construction of buildings designed to store Class IA and Class IB flammables. Explosion relief panels limit the damage within an enclosed hazardous location. When the panel(s) are subjected to an explosive force, the pressure relieving panel quickly vents the force before it causes major damage. The panels are designed to release at 20 psf.
Lighting & Electrical
OP0001 - Explosion Proof Interior Light with Switch
OP0001A - Additional Explosion Proof Interior Light
OP0001-LED - Explosion Proof LED Interior Light with Switch
OP0002 - Explosion Proof Exterior Light with Photo Cell
OP0005 - Explosion Proof Receptacle
HVAC (Insulation OP0009 Recomended)
OP0006-6 - Explosion Proof Heater [6,143 BTU]
OP0006-12 - Explosion Proof Heater [12,286 BTU]
OP0006-24 - Explosion Proof Heater [24,000 BTU]
OP0007-14 - Explosion Proof A/C [14,000 BTU]
OP0007-19 - Explosion Proof A/C [19,000 BTU]
OP0013 - Explosion Proof Exhaust System
IF Needed, Exhaust will run 24/7 (please Check if selecting OP0013)
Safety & Protection
OP0010 - Dry Chemical Fire Suppression System
OP0010A - Dry Chemical Alarm
OP0011 - Water Sprinkler System with 1" NPT Feed
OP0012 - Water Sprinkler System with Fire Hose Adapter
OP0014 - Liquid Level Detector with Alarm
OP0015 - HDPE Sump Liner -- .04" Thick (Plastic Welded)
OP0023 - Grounding Kit (8 Ft. Rod, 10 Ft. Cable with Clamps)
OP0025-6 - 6 Gallon Gravity Fed Eyewash Station
OP0025-16 - 16 Gallon Gravity Fed Eyewash Station
OP0028 - Portable Fire Extinguisher -- 10 Lbs. Capacity
Doors & Flooring
OP0021-36 - Additional 80"H x 36"W Door
OP0021-42 - Additional 80"H x 42"W Door
OP0021-60 - Additional 80"H x 60"W Double Door
OP0024-F - Fiberglass Floor Grating
OP0024-GS - Galvanized Steel Floor Grating
Ramps
BR60 - Ramp 24" x 72"
BR60A - Aluminum Ramp 24" x 72"
BR70 - Diamond Plated Ramp 44" x 88"
BR80 - Diamond Plated Ramp 52" x 72"
Miscellaneous
OP0009 - R-11 Insulation (Standard in AG Models)
OP0022 - Shelving, 14"W with 2" Raised Edges (Standard in AG Models)
Fire Rating According to FM
Securall Fire-Rated Storage Buildings (8'4"H X 42'W X 9'D Max Dimensions) carry the Factory Mutual System Approval label and have an FM Approved Fire Rated Wall & Roof Design. Wall and Roof are Tested at Intertek Testing Laboratories. Securall Fire-Rated Storage Buildings constructed based upon UL Fire Resistance Ratings classification criteria. Standard models are available in 2-hour and 4-hour fire ratings. Wall ratings are either 2 or 4 hour fire rated . Roof ratings are either 1.5 or 3 hour fire rated (Check with your local authority having jurisdiction for correct wall/roof rating needed). In addition, all Fire-Rated Buildings come with hydraulic operated self-closing, fire-rated doors and fire damper protected vents.
Industry's 1st & Only Intertek Tested and FM Approved 2 Hour Fire Rated wall construction built with 1.5 hour fire rated roof construction, 1.5 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.
Industry's 1st & Only Intertek Tested and FM Approved 4 Hour Fire Rated wall construction built with 3 hour fire rated roof construction, 3 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.
Please check with your local authority having jurisdiction for setback requirements and correct wall/roof rating needed.
Construction Features :
- Models B200 through B1200 Exterior Walls: 16 gauge galvannealed steel.
- Models B1600 through B8000 Exterior Walls: 12 gauge galvannealed steel.
- Interior Walls: 20-gauge galvannealed steel (3" air space between walls)
- Sump: 12-gauge steel liquid tight, continuously welded.
- Grating: Removable galvanized steel (Optional)
- Forklift channel: 12 gauge galvanized steel
- Grounding: NFPA & OSHA Compliant Static ground connection inside and out on all explosion rated models
- Labeling: NFR warning label, Hazard Ratings System, Instructions
- Venting: Natural convection vents
- Explosion Relief Panels: 22 gauge steel opening protected by expanded steel
- Available with 2 or 4 hour fire rating
- Chemical/corrosive/ultraviolet resistant paint
- Removable galvanized steel safety floor planking
Safety Floor Planking
Slip resistant planking 13" wide, 12 gauge galvanized steel with raised perforated buttons and debossed holes protruding down. Galvanized steel floor planking above sump area for maximum corrosion resistance. Floor planking designed to sustain a minimum uniformly distributed load of 250 pounds per square foot. Floor planking and supports are removable to facilitate sump cleaning in the event of a spill.
Door Style
Door for B200-B400 Provide one (42" wide x 62.5”) and B600-B1200 Provide one (42” wide x 80”) high door to facilitate the unloading and loading of hazardous material within the building. Installed with a UL Classified commercial grade keyed lockset. The door shall serve as personnel entrance and exit.
Door for B1600-B8000 Provide one 60” wide x 80” high double door to facilitate the unloading and loading of hazardous material within the building. Installed with a UL Classified commercial grade keyed lockset. The double door shall have one active leaf to serve as personnel entrance and exit. The active leaf must be equipped with a door closer available on B600-B1200 fire rated models.
Explsion Relief Panel
Used in the construction of buildings designed to store Class IA and Class IB flammables. Explosion relief panels limit the damage within an enclosed hazardous location. When the panel(s) are subjected to an explosive force, the pressure relieving panel quickly vents the force before it causes major damage. The panels are designed to release at 20 psf.
Factory Mutual System Approval
Securall Fire-Rated Hazardous Material Storage Buildings (10'H X 42'W X 9'D Max Dimensions) carry the Factory Mutual System Approval label and are constructed based upon UL Fire Resistance Ratings classification criteria. In addition, all Fire-Rated Buildings come with hydraulic operated self-closing, fire-rated doors and fire damper protected vents.
Hurricane Resistant Wall
Securall Buildings have been tested to determine the amount of force they can withstand and were shown to withstand F-4 tornado force winds of 250 mph. The chart below demonstrates the wind speed that a particular length of wall will resist.
Upgrade package is available for Tornado Resistant Walls.
Exterior Wall Construction
Securall Hazamat Storage Buildings are all-welded using 12 gauge (B1600X-B8000X Models) and 16 gauge (B200X-B1200X Models) galvannealed steel outer walls and 20 gauge cold rolled steel inner walls provide maximum durability, weather resistance, and rigidity.